P2 Power Solutions Pvt. Ltd.

Construction Industries Solution

Construction Industries Solution

Typical Challenges

  • Hunting of Diesel Generator even at partial loading condition
  • Heating of DG alternator
  • Low power factor leading to increased reactive stress

 

Root Cause Analysis

  • Complex load profile of heavy construction machines such as crane and welding demanding high reactive power which DG sets are not designed to supply
  • Increased reactive stress on DG due to sudden spikes/jerks in reactive power
  • Inflated peak kVA demand due to transitory reactive jerks

 

Solution

  • P2 Power Hybrid Filter at DG incomer (p2p-415-hf3)
  • P2 Power Hybrid Filter at DG incomer (p2p-415-hf4) - in case neutral current is high

 

Benefits

  • Reduced reactive stress on generator and therefore reduced peak demand
  • Elimination of DG hunting and alternator heating
  • Reduced fluctuations in peak power demand on the generator
  • Prevention of de-rating of available capacity; generator can be loaded to its maximum capacity
  • Lower capacity generators can be used to support entire load thus resulting in significant savings in capital expenditure on over sized DG sets
  • Reduced current harmonic distortion
  • Same active/hybrid filter installation can be used to improve power factor on grid supply as well

Enquiry Now




Close

Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us